2-wire Digital Panel Meters (Loop Powered) 6-UNIT Digital Meters
4-digit, Input Loop Powered
- 70 mm dia. , D 21 mm (6DV, 6DVI)
- W 110 x H 118 x D 92 mm (6DV-B, 6DVI-B)
- 4-digit red LED (-1999 to 9999)
- 4-20 mA input powered
- No external power source required
- Scaling & linearization selectable via the front control buttons
- Mountable on top of head-mount transmitter, installed together in an outdoor encloure (6DV, 6DVI)
- NEMA 4X, IP66 / IP67 (6DV-B, 6DVI-B)
Depending on the model.
-
2-wire Loop Powered LED Indicator with Intrinsically safe approval
Model 6DV is a 4-digit, 8-mm-high (.3”), 7-segment red LED display, which is powered from a 2-wire current loop (4 to 20 mA), requiring no extra power source. The maximum voltage drop caused by inserting the 6DV into the loop is 4.0 V at 20 mA.
· The display range is programmable from -1999 to 9999 and the decimal point is also selectable (10–1, 10–2, 10–3 or without decimals).
· Programmable functions include input signal calibration, offset setting and linearization (SQRT, RT32 and RT52, and 21-point user’s table).
· In combination with Model 27HU, it provides the user with a low-cost, field-mounted HART Temperature Transmitter with LED Display.
· Compact housing: External dimensions of 70mm-dia. (2.76”) and 21mm-high (.83”) (See below Figure 1).
Figure 1. External view and dimensions of 6DV, 6DVIUsing the A-34 DIN Rail Adaptor or the A-6 Spacer, various mounting styles are available.
-
Intrinsically safe approvals are available from ATEX Directive (Europe) and FM (US, Canada). Differences between the 6DV and the 6DVI exist only in safety parameters (See Table 1).
A safety barrier with matching safety parameters to the 6DV or 6DVI must be installed for complete intrinsic safety. The safety barrier should meet the Ex-data of this unit and must be approved for hazardous location.Table 1
Operating Temperature Temp Class Operating Temperature 6DV 6DVI FM/ATEX T4 Intrinsically safe T4 -40 to +80°C -40 to +85°C T5 -40 to +60°C -40 to +60°C Intrinsic Safety Ex Data 6DV 6DVI Ui (Vmax) 30V DC 28V DC Ii (Imax) 100mA DC 120mA DC*1 Pi (Pmax) 0.75W 0.84W Ci 1.0 nF 1.0 nF Li 0 mH 0 mH *1. Max. current allowed for the safety approval; Not to guarantee the product’s performance.
-
Model 6DV and 6DVI are approved to applicable standard of IEC60079 category: ia, and can be installed into hazardous areas Zone 0 (Europe) and Division 1 (US, Canada). They are covered for use in a potentially explosive atmosphere of the gas group (explosion group) including Hydrogen and Acetylene (See Table 2).
The 6DV and 6DVI Series also include an optional outdoor enclosure, model 6DV-B and 6DVI-B, which are able to be field-mounted.Table 2
Safety Approval FM: Intrinsically safe Class I, Div. 1, Groups A, B, C and D Class I, Zone 0, AEx ia IIC (US) Class I, Zone 0, Ex ia IIC (Canada) T4 and T5 (Class 3600) (Class 3610) (ANSI/ISA 60079-0) (ANSI/ISA 60079-11) (CAN/CSA-C22.2 E60079-0) (CAN/CSA-C22.2 E60079-11) TIIS: Intrinsic safety (6DV) Ex ia IIC T5 ATEX: Intrinsic safety II 1G, Ex ia IIC; T4, T5, Ga (EN 60079-0) (EN 60079-11) -