Current Transformer (CT) Input

  • 1 A or 5 A input, true RMS sensing, low cost
    0-1 A or 0-5 A
    100-240 V AC or 24 V DC powered (CE for 24 V DC type)
    True RMS sensing
    M5CT
    M5CT CEUKCA
  • 10-600 A current sensor input, low cost
    Wide input range from 10 A up to 600 A
    100-240 V AC or 24 V DC powered
    M5CTC
    M5CTC
  • 1 A or 5 A input, true RMS sensing
    0-1 A or 0-5 A
    100-240 V AC or 24 V DC powered
    UL/cUL Class I, Div. 2 approval
    M2CE
    M2CE CEULcULUKCA
  • 1 A or 5 A input, average sensing
    0-1 A or 0-5 A
    100-240 V AC or 24 V DC powered
    UL/cUL Class I, Div. 2 approval
    M2CA
    M2CA CEULcULUKCA
  • 10-600 A current sensor input
    Wide input range from 10 A up to 600 A
    Wide frequency range 50 / 60 / 400 Hz
    100-240 V AC or 24 V DC powered
    M2CEC
    M2CEC
  • 1 A or 5 A input signal splitter, true RMS sensing
    0-110 V or 0-150 V
    Independent current/voltage output ranges can be specified.
    100-240 V AC or 24 V DC powered
    UL/cUL Class I, Div. 2 approval
    W2CE
    W2CE CEULcULUKCA
  • 1 A or 5 A input signal splitter, average sensing
    0-110 V or 0-150 V
    Independent current/voltage output ranges can be specified.
    100-240 V AC or 24 V DC powered
    UL/cUL Class I, Div. 2 approval
    W2CA
    W2CA CEULcULUKCA
  • 10-600 A current sensor input, ultra-slim
    Wide input range from 10 A up to 600 A
    24 V DC powered
    M6
    M6SCTC Tension-Clamp Type CE
    M6NCTC Screw Terminal Type CE
    M6DCTC Euro Terminal Type CE

Voltage Transformer (VT) Input

  • 110, 150, 220 V input, true RMS sensing, low cost
    0-110 V, 0-150 V or 0-220 V
    100-240 V AC or 24 V DC powered
    True RMS sensing
    M5PT
    M5PT
  • 110 or 150 V input, true RMS sensing
    0-110 V or 0-150 V
    100-240 V AC or 24 V DC powered
    UL/cUL Class I, Div. 2 approval
    M2PE
    M2PE CEULcUL
  • 110 or 150 V input, average sensing
    0-110 V or 0-150 V
    100-240 V AC or 24 V DC powered
    UL/cUL Class I, Div. 2 approval
    M2PA
    M2PA CEULcUL
  • 110 or 150 V input , true RMS sensing
    0-110 V or 0-150 V
    Independent current/voltage output ranges can be specified.
    UL/cUL Class I, Div. 2 approval
    W2PE
    W2PE CEULcUL
  • 110 or 150 V input, average sensing
    0-110 V or 0-150 V
    Independent current/voltage output ranges can be specified.
    UL/cUL Class I, Div. 2 approval
    W2PA
    W2PA CEULcUL

AC Voltage & Current Input

  • AC voltage/current input
    Specific input range within 0-250 V or 0-1 A
    Min. 40 Hz, max. 1 kHz
    100-240 V AC or 24 V DC powered
    UL/cUL Class I, Div. 2 approval
    M2AC
    M2AC CEULcULUKCA
  • AC voltage/current input signal splitter
    Specific input range within 0-250 V or 0-1 A
    Min. 40 Hz, max. 1 kHz
    Independent current/voltage output ranges can be specified.
    100-240 V AC or 24 V DC powered
    UL/cUL Class I, Div. 2 approval
    W2AC
    W2AC CEULcUL

Tachogenerator Input

  • Tachogenerator (tachometer) input
    Specific input range within 0-250 V
    Min. 15 Hz, max. 1 kHz
    100-240 V AC or 24 V DC powered
    UL/cUL Class I, Div. 2 approval
    M2TG
    M2TG CEULcUL
  • Tachogenerator (tachometer) input signal splitter
    Specific input range within 0-250 V
    Min. 15 Hz, max. 1 kHz
    Independent current/voltage output ranges can be specified.
    100-240 V AC or 24 V DC powered
    UL/cUL Class I, Div. 2 approval
    W2TG
    W2TG CEULcUL