Application Notes
Trend & Log / Communication

The old company name and logo may still be indicated on products, printed materials or web site published before its change. Those shall be read as the new ones.

Isolation / Temperature / Pulse / Strain Gauge / Potentiometer / AC
Pneumatic / Function / Power Supply / Alarm / Power Mesurement
Trend & Log/Communication / Surge Protection / Other Topics

032040 Single point telemetering
[ HTML ] [ MS Word MS Word 108k ]
032043 Ethernet -- you still need to specify the protocol
[ HTML ] [ MS Word MS Word 56k ]
032044 Using the R1M in conjuntion with Citect 5 -- remote I/O SCADA/HMI software package
[ HTML ] [ MS Word MS Word 108k ]
032045 R1M Application
[ HTML ] [ MS Word MS Word 152k ]
032071 We are using R1M-J3 (I/O Module for RTD input) to monitor temperature.
Is there any way to set the PC Recorder store data only when input is between a specified temperature ranges?
[ HTML ] [ MS Word MS Word 473k ]
032072 This is an application for a twin tower hotel. There are about 100 guest rooms and the hotel wants to monitor the water flow of each guest room. Flow meter will be used to sense the water flow, from which voltage pulse will be generated. How can we configure a monitoring system for the customer?
[ HTML ] [ MS Word MS Word 142k ]
032073 We have an application similar to the one on previous issue. This one is a hotel with larger scale. They have 800 guest rooms and want to monitor the water flow from flowmeter at each room. Is M-System PC recorder capable in handling this?
[ HTML ] [ MS Word MS Word 192k ]
032086 We monitor indoor temperature of clean medical safekeeping room.
We put in temperature-measuring devices at several places and measure the temperature of the room. Even if one of the temperature-measuring device rise in temperature than rated value, we want to give an alarm as output.
Also, we want to monitor temperature changes on PC at control room. Does M-System have suitable unit for this application.

[ HTML ] [ MS Word MS Word 200k ]
032087 PC RECORDER APPLICATIONS – Part 1
Total Pollutant Load Control for Industrial Wastewater
[ HTML ] [ MS Word MS Word220k ]
032089 PC RECORDER APPLICATIONS – Part 2
Tap Water Supply Leakage Alarm
[ HTML ] [ MS Word MS Word415k ]
032092

We are trying to examine temperature distribution in a furnace by using a PC.We plan to connect ten points of K type T/C sensors to a recorder and measure the temperature distribution on the PC software. Measuring temperature is around 500°C and we are going to implant each T/C sensor in each test material and then let them move through a conveyor in the furnace so that we can get temperature distribution data.Do you have a suitable recorder hardware and software for this application?
[ HTML ] [ MS Word MS Word136k ]

032093 PC RECORDER APPLICATIONS – Part 3
Power Monitoring System
[ HTML ] [ MS Word MS Word240k ]
032095 PC RECORDER APPLICATIONS – Part 4
Monitoring at Multiple PCs via Ethernet
[ HTML ] [ MS Word MS Word230k ]
032097 PC RECORDER APPLICATIONS – Part 5
Upgrading Local Paper Recorder to Network Recording System
[ HTML ] [ MS Word MS Word120k ]
032098

We plan to monitor the amount of power usage of each facility in our factory. Because we set up “Demand Contracts” with Electric Power Company, we do monitor the receiving power amount. In addition, we’d like to confirm the status of power use of each facility.
Does M-System have suitable system or module?
[ HTML ] [ MS Word MS Word215k ]

032099 PC RECORDER APPLICATIONS – Part 6
Test Data Monitoring for Solar Power Generation System
[ HTML ] [ MS Word MS Word307k ]
032101 PC RECORDER APPLICATIONS – Part 7
Emergency Supervision for Power Facilities
[ HTML ] [ MS Word MS Word620k ]
032103 PC RECORDER APPLICATIONS – Part 8
Air Delivery System Monitoring
[ HTML ] [ MS Word MS Word835k ]
032107 PC RECORDER APPLICATIONS – Part 9
Environmental Monitoring
[ HTML ] [ MS Word MS Word192k ]
032109 PC RECORDER APPLICATIONS – Part 10
Pulp and Paper Application
[ HTML ] [ MS Word MS Word596k ]
032111 PC RECORDER APPLICATIONS – Part 11
Gravure Printing Application
[ HTML ] [ MS Word MS Word280k ]
032113 PC RECORDER APPLICATIONS – Part 12
Pump Station Monitoring Using Paperless Recorder
[ HTML ] [ MS Word MS Word332k ]
032114 At a control room, we plan to collect field data provided by test equipment. Each test equipment is installed in each three (3) measuring locations. There is 10-point temperature measuring point (thermocouple) in each location.
We’d like to build a PC based data acquisition system. Below listed measuring conditions are required.
1. Need to be set the data recording start/stop status via trigger input.
2. Need to be created each recorded file for each measuring point.
Does M-System have any suitable device and software?
[ HTML ] [ MS Word MS Word136k ]
032117 PC RECORDER APPLICATIONS – Part 13
Water Distribution Facilities
[ HTML ] [ MS Word MS Word760k ]
032119 PC RECORDER APPLICATIONS – Part 14
Temperature Monitoring at Food Manufacturing Plant
[ HTML ] [ MS Word MS Word204k ]
032121 PC RECORDER APPLICATIONS – Part 15
AC Current Monitoring at Hospital's Surgical Facility
[ HTML ] [ MS Word MS Word228k ]
032122 We plan to monitor working situation of plant equipment at control room. When field equipment has working trouble, it will provide discrete status signal as working error and we'd like to check it at control room.
8 discrete signals will be required to monitor at the control room. The distance between the field equipment and the field panel is approx. 50 meters. Between the field panel and the control room is approx. 200 meters. We'd like to let the warning light on at both field panel end and control room end. Does M-System have any solution with low cost?
[ HTML ] [ MS Word MS Word696k ]
032123 PC RECORDER APPLICATIONS – Part 16
Power Monitoring at a Large Shopping Mall
[ HTML ] [ MS Word MS Word172k ]
032125 PC RECORDER APPLICATIONS – Part 17
Data Acquisition from Fuel Cell Test Equipment
[ HTML ] [ MS Word MS Word408k ]
032126 To monitor 3-phase motor’s leakage current, we’d like to use a Zero-phase-sequence Current Transformer (ZCT) and detect zero-phase current when earth-faulting. We want to monitor the current by a PC.
Does M-System have any suitable system/module?
[ HTML ] [ MS Word MS Word208k ]
032127 PC RECORDER APPLICATIONS – Part 18
Paperless recorder for the sterilizer system at food manufacturing plant
[ HTML ] [ MS Word MS Word168k ]
032130 PC RECORDER APPLICATIONS – Part 19
Temperature monitoring of continuous kiln
[ HTML ] [ MS Word MS Word372k ]
032134 PC RECORDER APPLICATIONS – Part 20
Temperature monitoring at a synthetic fiber plant
[ HTML ] [ MS Word MS Word196k ]
032141 We are using M-System paperless recorder, 73VR2100, which is collecting various data of factory equipments continuously while the factory is in operation. We shut down factory power after finishing daily operation per each day. We are informed that the 73VR’s data in CF card could be lost if power off the unit during data logging. Do you have any solution? We’d like to let the 73VR stop recording before factory power off and then start recording after factory power on every morning.
[ HTML ] [ MS Word MS Word172k ]
032145 We have a leased equipment at our factory. To check the leased charge, we like to display and record the operating time during a day by a recorder. There is “ON” contact signal only available from equipment while operating. Using that signal, the operating time needs to know by the minute. Is there a solution?
[ HTML ] [ MS Word MS Word 156k ]