Trend & Log/Communication / Surge Protection / Other Topics

031080 We are now using the potentiometer transmitter for the potentiometer (0 -3k ohms) at site. But we are forced to change this potentiometer (0-3k ohms) to another potentiometer (0-2k ohms)….
[ HTML ] [ MS Word MS Word 104k ]
031081 In ratio control, I need to change the ratio manually at the front of the panel.
[ HTML ] [ MS Word MS Word 112k ]
031082 Automated control of inverter frequency - applying DC/potentiometer converter
[ HTML ] [ MS Word MS Word 88k ]
031083 Do you have a remote settable potentiometer?
[ HTML ] [ MS Word MS Word 148k ]
031085 Water flow based on a level signal in a waterway is being measured. Can I have a transmitter which provides an output linear to the flow? The level signal is transmitted by a potentiometer with a resistance value linear to the level.
[ HTML ] [ MS Word MS Word 104k ]
031086 I am looking for a signal conditioner which can output either 0V or 10V DC by switching ON-OFF contact.
[ HTML ] [ MS Word MS Word 148k ]
032062 We are now using the potentiometer transmitter; model: M2MS for the potentiometer (0 to 3k ohms) at site. But we are forced to change this potentiometer (0 to 3k ohms) to another potentiometer (0 to 2k ohms).
[ HTML ] [ MS Word MS Word 88k ]
032079 There is a deck gun for fire protection in a garbage incinerator site. We are thinking to use a potentiometer for detecting the traverse angle and elevation angle of the deck gun. We want to transfer the angle signal to a control room at 200-meter distance from the field. We’d like to minimize the field panel size as much as possible, hence we think to install a potentiometer transmitter at the control room and wire the signal from the field’s potentiometer sensor to the control room. Is this a realistic idea for us to wire the sensor for 200 meters?
[ HTML ] [ MS Word MS Word 220k ]
032085 We plan to install a damper gear on fresh air supply duct for air volume adjustment purpose.
We are going to measure the damper gate opening/shutting signal on the indicator at field end and control room end. The damper gear includes 125 ohm potentiometer as gate opening detector. We want to get 1-5 Vdc for field indication and 4-20 mAdc for control room indication.
Other condition we need is small sized conditioner so that we can install it into existing small field panel. Does M-System have the conditioner fit to this application?
[ HTML ] [ MS Word MS Word 204k ]
032090 We plan to replace an actuator at field. We are going to convert the actuator’s feedback potentiometer signal to a standard 4-20 mAdc signal and then we are going to transmit the 4-20 mA to control room for monitoring.
Does M-System have field-mounted 2-wire potentiometer transmitter? With regard to a power supply for the transmitter, we are going to use the current loop supply, the M5DY.

[ HTML ] [ MS Word MS Word 196k ]
032140 We use an inverter to control motor speed at factory production line.
A controller unit provides 4-20mA control signal and the inverter drives the motor.
On the 4-20mA line, we’d like to set low limit speed control adjustment manually by using potentiometer on the panel. Does M-System have any solution for this application?
[ HTML ] [ MS Word MS Word 256k ]
032151 We are looking for a simple Generator to output analog signals proportional to the set points of external contact ON signals. Do you have such a product?
[ HTML ] [ MS Word MS Word 76k ]


Isolation / Temperature / Pulse / Strain Gauge / Potentiometer / AC
Pneumatic / Function / Power Supply / Alarm / Power Mesurement
Trend & Log/Communication / Surge Protection / Other Topics