032030 Factory drainage pH control system -- applying analog positioner MEX
[ HTML ] [ MS Word MS Word 104k ]
032032 Cheminal feeder for Water treatment -- applying the Mini-top model MSP
[ HTML ] [ MS Word MS Word 112k ]
032033 Pulp Concentration control system
[ HTML ] [ MS Word MS Word 112k ]
032034 Combustion control of an Industrial Gas burner -- applying the Mini-top model MRP
[ HTML ] [ MS Word MS Word 112k ]
032035 M-System Mechatronics Series Application
[ HTML ] [ MS Word MS Word 184k ]
032037 Computer backup system -- applying analog backup station
[ HTML ] [ MS Word MS Word 100k ]
032038 I would like to install a manual staion in the field as backup device of a controller. And I want the manual staion to follow its input signal (output signal from host controller) with the preset response speed in switching manual operation to auto.
[ HTML ] [ MS Word MS Word 144k ]
032046 Rush current
[ HTML ] [ MS Word MS Word 108k ]
032060 Self-synch transmitters
[ HTML ] [ MS Word MS Word 56k ]
032061 Application of analog backup station
[ HTML ] [ MS Word MS Word 112k ]
032091 Backup hold & manual loading for the PID controller output failure
[ HTML ] [ MS Word MS Word 224k ]
032115 We have M-System’s Analog Backup Station Model AB.
Now we have a plan to replace an existing equipment and want to improve our flow control system. We require some additional function on this unit AB.
(1) When switched from MANUAL to AUTO mode, specific fixed value is required to be output.
(2) When start-up after put off the power, fixed preset valued initial output is required.
We considered adding an external circuit in order to get this function. Alternatively, we can consider replacing the AB with any other M-System product, which have this kind function. Please advise.
[ HTML ] [ MS Word MS Word 152k ]
032131 We are using the synchronous transmitter (SELF-SYNCH) to measure the opening angle of an intake gate in the river and send the output signal of the transmitter to the synchronous receiver in a control room to display the opening angle. As a result of monitor system standardization, we want to convert the output signal (opening angle signal) into a standardized signal of 4 to 20 mA in DC for instrumentation without replacing or modifying the existing synchronous transmitter. Is there any converter suitable for this purpose? The precise operating angle range of the synchronous transmitter is unknown.
[ HTML ] [ MS Word MS Word 116k ]
032148 We would like to display a 4-20mA DC signal from the two-wire level transmitter. Is there a product to display the water level with alarm output, and the alarm status can be visible?
[ HTML ] [ MS Word MS Word 71k ]
032152 We like to display a water level in a tank. The 4 to 20mA DC output from a level transmitter is for 0 to 5.00 meter of water level in a oval-shaped tank. Thus, water usage and decreased water level are not proportional. Is there a digital indicator to display water usage?
[ HTML ] [ MS Word MS Word 71k ]
032162 For the production of pasta, there is a mixing process of raw materials in a tank. The raw materials can be affected by heat. To prevent it, the water temperature surrounding a tank is adjusted by controlling the valves of cold-water and heated-water. This time, we are considering a PLC to control the temperature automatically. The DeviceNet communication bus is ideal to control the valves. Is there any suitable product?
[ HTML ] [ MS Word MS Word 76k ]