ISP 2014/2015 E
33/48

33RecordersSignalConditionersIndicatorsPowerTransducersWeb Data LoggersLimit AlarmsTower LightsPID ControlComponentsRemote I/OMultiplex Transmission SystemElectric ActuatorsLightning SurgeProtectorsTemperature ControllersSignal Conditioners Selection Guide 1Focused New Products for JapanSignal Conditioners Selection Guide 2M-SystemCompanyTC10 Series ❙Universal input configurable to T/C, RTD, DC current or voltage independently ❙Discrete input for remote trigger ❙Clamp-on current sensor input to detect wire breakdown or overload ❙Modbus RTUteMPeratUre ControllerSTC10NM1/8 DIN sizeOne PID loopTC10EM1/4 DIN sizeTwo PID loopsDCS IN INSTRUMENT FORMAT – Advanced Computation and Sequential Control FunctionsThe control and computation functions are achieved by combining a wide variety of basic to advanced function blocks, which are normally found only in DCS systems, 2 PID blocks, 48 computation blocks and 12 sequential control blocks (1068 commands) are available for all versions of the SC Series, applicable to a wide range of application fields.Sequential Control Commands BlocksField Terminal BlocksOperation BlocksControl BlocksNestBusNestBus TerminalNestBus TerminalCommunication Blocks• Di Receive Terminal• Do Send Terminal• Basic PID• Advanced PID• Manual loader• Ratio setter• Indicator• Ai Receive Terminal• Ao Send TerminalSC200 / SC210121161234567891011121234567891011121314151617181920212223242526272829303132Pulse Input• Pulse adder• Pulse/analog multiplication• Pulse accumulator• Pulse input / Discrete contact outputMath Functions• Addition / Subtraction• Multiplication• DivisionProcess Funstions• Square root extractor, Absolute value• Non-linear gain, Deadband• Low-end cutout• Temperature/pressure compensationFilters• First order lag, First order lag with two time constants• Ramp buffer• Mean average• Moving average• Lead time/dead time computation• Dead time compensation, Dead time accumulation• Rate of Change LimitAlarm• High/low alarm, Deviation alarm• Rate of change alarmOthers• Parameter setter• Numeral converter• Weight totalizer• Analog/pulse duration converter• Signal hold (max, min, momentary)Signal Limiters• High/low limiter, Deviation limiterSequential Control• Timer, CounterSignal Selectors• Input selector, Max value selector• Min value selector, Parameter selectorAnalog I/ODiscrete I/OFunction Block Structure18• Batch ProgramLarge Operation Blocks12345678• Linearizer• Ramp programEXCELLENT EXPANDABILITY – Peer-to-peer and Host CommunicationThe SC200/SC210 has Modbus (Ethernet TCP/IP or RS-485 RTU) which enables easy connection to logging or SCADA systems on a host PC for supervising and controlling the local I/O data.In addition, the RS-485 ‘NestBus’ enables peer-to-peer communication with other controllers and I/O devices for flexibility of I/O points.• Peer-to-peer• Host CommunicationPCNestBusModbus/TCP or Modbus RTUSCADASC200SC200SC210SC210SC200SC200I/O Module model: SMLExpanded System Configuration ExampleNEWNEW

元のページ 

10秒後に元のページに移動します

※このページを正しく表示するにはFlashPlayer10.2以上が必要です