Signal Conditioners

Universal Input Isolators DC mV, V, mA Input
Temperature Input Potentiometer Input Current Loop Supplies & Power Supplies
Strain Gauge Input AC Input Frequency I/O
Pneumatic Transducers Function Modules Isolation Amplifiers
Unique & Special    

Temperature Input

RTD output Application Notes

PC Programmable
m2x
Universal input, PC programmable
M2XU
CE UL cUL
  • DC mV, V & mA, T/C, RTD and Pot input
  • Output selectable within 0-20 mA and ±10 V
  • 100-240 Vac or 24 Vdc powered
  • 100-point linearization (DC and Pot input)
  • UL/cUL Class I, Div. 2 approval
Data Sheet Download (PDF)
m2x
Universal input, PC programmable; Modbus-RTU
M2XUM
CE
  • DC mV, V & mA, T/C, RTD and Pot input
  • Output selectable within 0-20 mA and ±10 V
  • 100-240 Vac or 24 Vdc powered
  • 100-point linearization (DC and Pot input)
Data Sheet Download (PDF)
m6
Universal input, PC programmable, ultra-slim type
M6SXU (Tension-Clamp Type)
CE RoHS
Data Sheet Download (PDF)
M6NXU (Screw Terminal Type)
CE RoHS
Data Sheet Download (PDF)
M6DXU (Euro Terminal Type)
CE RoHS
Data Sheet Download (PDF)
  • DC mV, V & mA, T/C, RTD and Pot input
  • Output selectable within 0-20 mA and ±10 V
  • 100-240 Vac or 24 Vdc powered
m3
Universal input, PC & "One-Step Cal" programmable
M3LU2
CERoHS
  • DC mV, V & mA, T/C, RTD, Pot and resistance input
  • Output selectable within 0-20 mA and ±10 V
  • 100-240 Vac or 24 Vdc powered (UL/cUL for 24 Vdc type)
  • DIP switch or PC configuration
  • 128-point linearization (DC input) using the PC Configurator (1000 points for T/C, 500 points for RTD)
Data Sheet Download (PDF)
m3
Universal input, PC & "One-Step Cal" programmable
M3LU
CE UL cUL RoHS
  • DC mV, V & mA, T/C, RTD, Pot and resistance input
  • Output selectable within 0-20 mA and ±10 V
  • 100-240 Vac or 24 Vdc powered (UL/cUL for 24 Vdc type)
  • DIP switch or PC configuration
  • 128-point linearization (DC input) using the PC Configurator (1000 points for T/C, 500 points for RTD)
Data Sheet Download (PDF)
m2x
T/C input, PC programmable
M2XT2
CE UL cUL RoHS
  • K, E, J, T, B, R, S, C, N, U, L, PL-II selectable
  • Output selectable within 0-20 mA and ±10 V
  • 100-240 Vac or 24 Vdc powered
  • UL/cUL Class I, Div. 2 approval
Data Sheet Download (PDF)
m2x
RTD input, PC programmable
M2XR2
CE UL cUL RoHS
  • Pt100, Pt1000, Pt50, Ni100, Ni508.4, Cu10 selectable
  • Output selectable within 0-20 mA and ±10 V
  • 100-240 Vac or 24 Vdc powered
  • UL/cUL Class I, Div. 2 approval
Data Sheet Download (PDF)
m6
T/C input, PC programmable, ultra-slim type
M6SXT (Tension-Clamp Type)
CE UL cUL RoHS
Data Sheet Download (PDF)
M6NXT (Screw Terminal Type)
CE UL cUL RoHS
Data Sheet Download (PDF)
M6DXT (Euro Terminal Type)
CE UL cUL RoHS
Data Sheet Download (PDF)
  • K, E, J, T, B, R, S, N selectable
  • Output selectable within 0-20 mA and ±10 V
  • 24 Vdc powered
m6
RTD input, PC programmable, ultra-slim type
M6SXR (Tension-Clamp Type)
CE UL cUL RoHS
Data Sheet Download (PDF)
M6NXR (Screw Terminal Type)
CE UL cUL RoHS
Data Sheet Download (PDF)
M6DXR (Euro Terminal Type)
CE UL cUL RoHS
Data Sheet Download (PDF)
  • Pt100, Pt1000, Pt50, Cu10 selectable
  • Output selectable within 0-20 mA and ±10 V
  • 24 Vdc powered
m3
T/C input, PC & "One-Step Cal" programmable
M3LT
CE UL cUL RoHS
  • K, E, J, T, B, R, S, C, N, U, L, PL-II selectable
  • Output selectable within 0-20 mA and ±10 V
  • 10-32 Vdc powered
  • DIP switch or PC configuration
  • 300-point linearization using the PC Configurator
Data Sheet Download (PDF)
m3
RTD input, PC & "One-Step Cal" programmable
M3LR
CE UL cUL RoHS
  • Pt100-1000, Pt50, Ni100, 120, 508.4, Ni-Fe 604, Cu10 selectable
  • Output selectable within 0-20 mA and ±10 V
  • 10-32 Vdc powered
  • DIP switch or PC configuration
  • 300-point linearization using the PC Configurator
Data Sheet Download (PDF)
m3
T/C input, PC programmable, thin profile type
M3SXT
CE RoHS
  • K, E, J, T, B, R, S, N selectable
  • Output selectable within 0-20 mA and ±10 V
  • 100-240 Vac / 24 Vdc universal power input
Data Sheet Download (PDF)
m3
RTD input, PC programmable, thin profile type
M3SXR
CE RoHS
  • Pt100, Pt1000, Pt50, Cu10 selectable
  • Output selectable within 0-20 mA and ±10 V
  • 100-240 Vac / 24 Vdc universal power input
Data Sheet Download (PDF)
 
PC Programmable Signal Splitters
W2
T/C input signal splitter, PC programmable
W2XT
RoHS
  • K, E, J, T, B, R, S, C, N, U, L, PL-II selectable
  • Output selectable within 0-20 mA and ±10 V
  • 100-240 Vac or 24 Vdc powered
Data Sheet Download (PDF)
W2
RTD input signal splitter, PC programmable
W2XR
RoHS
  • Pt100, Pt1000, Pt50, Cu10 selectable
  • Output selectable within 0-20 mA and ±10 V
  • 100-240 Vac or 24 Vdc powered
Data Sheet Download (PDF)
Fixed Range
M2
T/C input, fixed range
M2TS
CE UL cUL RoHS
  • Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable
  • 100-240 Vac or 24 Vdc powered
  • Fast response 25 msec. optional
  • UL/cUL Class I, Div. 2 approval
Data Sheet Download (PDF)
M2
T/C input, fixed range
M2TTNEW
CE
  • Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable
  • 100-240 Vac or 24 Vdc powered
  • Fast response 25 msec. optional
  • Operating temperature: -20 to +80 °C (-4 to +176°F)
Data Sheet Download (PDF)
M2
RTD input, fixed range
M2RS1NEW
CE
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable
  • 100-240 Vac or 24 Vdc powered
  • Fast response 25 msec. optional
  • 1 mA sensing current (except Cu Input)
Data Sheet Download (PDF)
M2
RTD input, fixed range
M2RS
CE UL cUL RoHS
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable
  • 100-240 Vac or 24 Vdc powered
  • Fast response 25 msec. optional
  • UL/cUL Class I, Div. 2 approval
Data Sheet Download (PDF)
M2
RTD input, fixed range
M2RTNEW
CE
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable
  • 100-240 Vac or 24 Vdc powered
  • Fast response 25 msec. optional
  • Operating temperature: -20 to +80 °C (-4 to +176°F)
Data Sheet Download (PDF)
M5
T/C input, fixed range, low cost
M5TS
CE RoHS
  • Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable
  • 100-240 Vac or 24 Vdc powered (CE for 24 Vdc type)
  • Fast response 25 msec. optional
Data Sheet Download (PDF)
M5
RTD input, fixed range, low cost
M5RS
CE RoHS
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable
  • 100-240 Vac or 24 Vdc powered (CE for 24 Vdc type)
  • Fast response 25 msec. optional
Data Sheet Download (PDF)
 
Fixed Range Signal Splitters
W2
T/C input signal splitter, fixed range
W2TS
CE UL cUL RoHS
  • Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable
  • Independent current/voltage output ranges can be specified
  • 100-240 Vac or 24 Vdc powered
  • Fast response 25 msec. optional
  • UL/cUL Class I, Div. 2 approval
Data Sheet Download (PDF)
W2
RTD input signal splitter, fixed range
W2RS
CE UL cUL RoHS
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable
  • Independent current/voltage output ranges can be specified
  • 100-240 Vac or 24 Vdc powered
  • Fast response 25 msec. optional
  • UL/cUL Class I, Div. 2 approval
Data Sheet Download (PDF)
W5
T/C input signal splitter, fixed range, low cost
W5TS
CE RoHS
  • Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable
  • Independent output ranges selectable
  • CE marking for 24 Vdc powered
  • Fast response 25 msec. optional
Data Sheet Download (PDF)
W5
RTD input signal splitter, fixed range, low cost
W5RS
CE RoHS
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable
  • Independent output ranges selectable
  • CE marking for 24 Vdc powered
  • Fast response 25 msec. optional
Data Sheet Download (PDF)
Page top

M-System Products Guide

Series Selection Guide Two-wire Signal Conditioners