Signal Conditioners

Universal Input Isolators DC mV, V, mA Input
Temperature Input Potentiometer Input Current Loop Supplies & Power Supplies
Strain Gauge Input AC Input Frequency I/O
Pneumatic Transducers Function Modules Isolation Amplifiers
Unique & Special    

Frequency I/O

Application Notes

Pulse to Analog
M3
PC & "One-Step Cal" programmable I/O
M3LPA2
CE UL cUL Green
  • Open collector, dry contact, voltage pulse, two-wire current, RS-422 line driver selectable; 0-200 kHz max.
  • Excitation 4 V, 8 V or 12 V selectable
  • Output selectable within 0-20 mA and ±10 V
  • 100-240 Vac or 24 Vdc powered
  • DIP switch or PC configuration
  • 101-point linearization using the PC Configurator
Data Sheet Download (PDF)
M2X
PC programmable I/O
M2XPA3
CE UL cUL Green
  • Open collector, mechanical contact, voltage pulse, two-wire current, RS-422 line driver selectable; 0-200 kHz max.
  • Excitation 4 V, 8 V or 12 V selectable
  • Output selectable within 0-20 mA and ±10 V
  • 100-240 Vac or 24 Vdc powered
  • UL/cUL Class I, Div. 2 approval
Data Sheet Download (PDF)
M2
Fixed range
M2SP
CE UL cUL Green
  • Dry contact or voltage pulse. Specific input range up to 10 kHz
  • Excitation 12 V @30 mA
  • 100-240 Vac or 24 Vdc powered
  • UL/cUL Class I, Div. 2 approval
Data Sheet Download (PDF)
W2
Fixed range signal splitter
W2SP
CE UL cUL Green
  • Dry contact or voltage pulse. Specific input range up to 10 kHz
  • Excitation 12 V @30 mA
  • Independent current/voltage output ranges can be specified.
  • 100-240 Vac or 24 Vdc powered
  • UL/cUL Class I, Div. 2 approval
Data Sheet Download (PDF)
M6
Fixed range, ultra-slim type
M6SPA (Tension-Clamp Type)
CE UL cUL Green
Data Sheet Download (PDF)
M6NPA (Screw Terminal Type)
CE UL cUL Green
Data Sheet Download (PDF)
M6DPA (Euro Terminal Type)
CE UL cUL Green
Data Sheet Download (PDF)
  • Open collector, mechanical contact, 5V/24V pulse. Specific input range up to 100 kHz
  • 24 Vdc powered
M5
Fixed range, low cost
M5PA
CE Green
  • Open collector, mechanical contact, 5V/12V/24V pulse. Specific input range up to 100 kHz
  • 100-240 Vac or 24 Vdc powered (CE for 24 Vdc type)
Data Sheet Download (PDF)
W5
Fixed range signal splitter, low cost
W5PA
CE Green
  • Open collector, mechanical contact, 5V/12V/24V pulse. Specific input range up to 100 kHz
  • Independent output ranges selectable
  • 100-240 Vac or 24 Vdc powered (CE for 24 Vdc type)
Data Sheet Download (PDF)
 
Analog to Pulse
M2
Fixed range frequency output
M2AP
CE UL cUL
  • Specific input range up to 300 V
  • Open collector, 5V pulse or mercury relay output. Specific output range up to 1 kHz.
  • 100-240 Vac or 24 Vdc powered
  • UL/cUL Class I, Div. 2 approval
Data Sheet Download (PDF)
W2AP
Fixed range frequency output signal splitter
W2AP
CE UL cUL Green
  • Specific input range up to 300 V
  • Open collector, 5V pulse or mercury relay output. Specific output range up to 10 kHz.
  • 100-240 Vac or 24 Vdc powered.
  • UL/cUL Class I, Div. 2 approval
Data Sheet Download (PDF)
Pulse Isolation, Scaling
M2X
Pulse isolator
M2PP
CE UL
  • Mechanical contact, open collector or voltage pulse input; 0-10 kHz max.
  • Open collector, voltage pulse or mercury relay output
  • 100-240 Vac or 24 Vdc powered
  • UL Class I, Div. 2 approval
Data Sheet Download (PDF)
M2X
Pulse scaler
M2PRU
CE UL cUL Green
  • Open collector, mechanical contact, 5V pulse or two-wire current pulse input; 0-100 kHz max.
  • Excitation 12 V/24 V @30mA
  • Open collector, voltage pulse, AC/DC switch output
  • Scaling factor adjustable of 1.000 x 1/1 to 0.0001 x 1/1000000
  • 100-240 Vac or 24 Vdc powered
  • UL/cUL Class I, Div. 2 approval
Data Sheet Download (PDF)
W2PP
Pulse isolator, signal splitter
W2PP
CE
  • Mechanical contact, open collector or voltage pulse input; 0-10 kHz max.
  • Open collector, voltage pulse or Dry contact AC/DC switch output
  • 100-240 Vac or 24 Vdc powered
Data Sheet Download (PDF)
M6
Pulse isolator, ultra-slim type
M6SPP (Tension-Clamp Type)
CE Green
Data Sheet Download (PDF)
M6NPP (Screw Terminal Type)
CE Green
Data Sheet Download (PDF)
M6DPP (Euro Terminal Type)
CE Green
Data Sheet Download (PDF)
  • Mechanical contact, open collector, voltage pulse or two-wire current input; 0-100 kHz max.
  • Open collector or voltage pulse output
  • 24 Vdc powered
M_8P
Pulse isolator, selectable excitation
YPD
  • Dry contact, voltage pulse or two-wire current input; 0-100 kHz max.
  • Excitation 5 V or 12 V
  • Open collector, voltage pulse or relay contact output
  • 100, 110, 115, 120, 200, 220, 240 Vac or 12, 24, 48 Vdc powered
Data Sheet Download (PDF)
W_11P
Pulse isolator, signal splitter, selectable excitation
WYPD
  • Dry contact, voltage pulse or two-wire current input; 0-100 kHz max.
  • Excitation 5 V or 12 V
  • Open collector, voltage pulse or relay contact output (two)
  • 100, 110, 115, 120, 200, 220, 240 Vac or 12, 24, 48 Vdc powered
Data Sheet Download (PDF)
Encoder Input
M2X_W
PC programmable I/O, encoder input
M2XRP2
CE UL cUL Green
  • Converts a two-phase forward and reverse rotation pulse signal with 90 degree phase difference into a forward and reverse speed signal.
  • Open collector, voltage pulse, RS-422 line driver selectable; 0-100 kHz max.
  • Excitation 5 V or 12 V selectable
  • Output selectable within 0-20 mA and ±10 V
  • 100-240 Vac or 24 Vdc powered
Data Sheet Download (PDF)
M_14P
Rotary encoder speed input
JRP2
  • Converts a two-phase forward and reverse rotation pulse signal with 90 degree phase difference into a forward and reverse speed signal.
  • Open collector, voltage pulse or RS-422 line driver pulse inputs
  • Excitation 5 V, 12 V or 24 V
  • 85-132 Vac or 12, 24, 48, 110 Vdc powered

Applications: Measuring moving speed of a machine with a rotary encoder

Data Sheet Download (PDF)
M_14P
Rotary encoder position input
JRQ2
Green
  • Converts a two-phase forward and reverse rotation pulse signal with 90 degree phase difference into a forward and reverse position signal.
  • Open collector, voltage pulse or RS-422 line driver pulse inputs
  • Excitation 5 V, 12 V or 24 V
  • 85-132 Vac or 12, 24, 48, 110 Vdc powered

Applications: Measuring moving distance of a machine with a rotary encoder

Data Sheet Download (PDF)
W_11P
Rotary encoder pulse isolator
RPPD
CE Green
  • Galvanically isolates two pulse rate signals from a rotary encoder.
  • Dry contact, voltage pulse, two-wire current pulse, or RS-422 line driver pulse inputs.
  • Relay, open collector or voltage pulse outputs
  • Excitation 5 V, 12 V or 24 V
  • 85-132 Vac or 12, 24, 48, 110 Vdc powered

Applications: Isolating field pulse signals in order to reduce noise interference

Data Sheet Download (PDF)
Page top

M-System Products Guide

Series Selection Guide Two-wire Signal Conditioners