| SERIES |
M2 / W2 |
M6S |
M6N |
M6D |
| Enclosure/Mounting Type |
Plug-in base socket, DIN rail or surface mount |
Ultra-slim housing, DIN rail mount |
| Electric Wiring |
M3 screw |
Tension clamp |
M3 screw |
Euro terminal |
| I/O Range, Function Parameters |
Specified when ordering |
PC programmable |
| Power Input |
AC/DC |
DC |
| Isolation |
2000V AC |
2000V AC |
| Operating Temperature |
-5 to +55°C
(23 to 131°F) |
-20 to +55°C (-4 to +131°F) |
| Standards & Approval |
CE / UL / C-UL / RoHS |
CE / UL / C-UL / RoHS |
| FUNCTION |
M2 / W2 |
M6S |
M6N |
M6D |
| Temperature/pressure compensation |
|
M6SXF2 |
M6NXF2 |
M6DXF2 |
| Addition X0 = X1 + X2 |
M2ADS |
M6SXF2 |
M6NXF2 |
M6DXF2 |
| Subtraction X0 = X1 X2 |
M2SBS |
M6SXF2 |
M6NXF2 |
M6DXF2 |
| Multiplication X0 = X1 × X2 |
M2MLS |
M6SXF2 |
M6NXF2 |
M6DXF2 |
| Division X0 = X1 ÷ X2 |
M2DIS |
M6SXF2 |
M6NXF2 |
M6DXF2 |
| Ratio function X0 = KX1 + B |
M2REB |
|
|
|
| Ratio function X0 = K(X1 + B) |
M2RTS |
|
|
|
| Delay buffer (1) |
M2CDS |
M6SXF1 |
M6NXF1 |
M6DXF1 |
| Ramp buffer (2) |
M2CRS |
M6SXF1 |
M6NXF1 |
M6DXF1 |
| Moving average |
|
M6SXF1 |
M6NXF1 |
M6DXF1 |
| Lead time / Dead time (3)(4) |
|
M6SXF1 |
M6NXF1 |
M6DXF1 |
| Linearization |
M2XF2, W2XF
(PC programmable) |
M6SXF1 |
M6NXF1 |
M6DXF1 |
| Square root extraction |
M2FLS |
M6SXF1 |
M6NXF1 |
M6DXF1 |
| Palmer-Bowlus flume, Parshall flume, triangular/v-notch/rectangular weir |
|
M6SXF1 |
M6NXF1 |
M6DXF1 |
| Inverted output (5) |
M2UDS, M2UDS2 |
M6SXF1 |
M6NXF1 |
M6DXF1 |
| High/low limiting (6) |
M2LMS |
M6SXF1 |
M6NXF1 |
M6DXF1 |
| Track/hold (7) |
M2AMS, M2AMS2 |
M6SXF3 |
M6NXF3 |
M6DXF3 |
| Peak hold (8) |
M2PHS, M2PHS2 |
M6SXF3 |
M6NXF3 |
M6DXF3 |
| High/low selecting |
M2SES, M2SES2 |
M6SXF2 |
M6NXF2 |
M6DXF2 |
| Switching two channels |
M2MNV |
|
|
|
| Parameter generator |
M2MST |
|
|
|
PC Programmable Universal I/O 128-point Linearizer
M3LU
CE UL cUL RoHS
- DC mV, V & mA, T/C, RTD, Pot and resistance input
- Output selectable within 0-20 mA and ±10 V
- 100-240 Vac or 24 Vdc powered
- DIP switch or PC configuration
|
PC Programmable 100-point Linearizer
M2XF2
CE UL cUL RoHS
- Input selectable within 0-50 mA and +/-10 V
- Output selectable within 0-20 mA and +/-10 V
- 100-240 Vac or 24 Vdc powered
- UL/cUL Class I, Div. 2 approval
|
PC Programmable 101-point Linearizer; Signal Splitter
W2XF
- Input selectable within 0-50 mA and +/-10 V
- Output selectable within 0-20 mA and +/-10 V
- 100-240 Vac or 24 Vdc powered
|
PC Programmable I/O, Ultra-Slim Type, Single-input
M6SXF1 (Tension-Clamp Type)
CE UL cUL RoHS
M6NXF1 (Screw Terminal Type)
CE UL cUL RoHS
M6DXF1 (Euro Terminal Type)
CE UL cUL RoHS
- Functions Filter / Lag, Linearization, Limiter
- Input selectable within 0-50 mA and ±10 V
- Output selectable within 0-20 mA and ±10 V
- 24 Vdc powered
|
PC Programmable I/O, Ultra-Slim Type, Two-input
M6SXF2 (Tension-Clamp Type)
CE RoHS
M6NXF2 (Screw Terminal Type)
CE RoHS
M6DXF2 (Euro Terminal Type)
CE RoHS
- Functions Math functions, Hi/Low signal selector
- Input selectable within 0-50 mA and ±10 V
- Output selectable within 0-20 mA and ±10 V
- 24 Vdc powered
|
PC Programmable I/O, Ultra-Slim Type,
hold function module
M6SXF3 (Tension-Clamp Type)
CE RoHS
M6NXF3 (Screw Terminal Type)
CE RoHS
M6DXF3 (Euro Terminal Type)
CE RoHS
- Track/Hold or Pesk hold function's selection available
- Input selectable within 0-50 mA and ±10 V
- Output selectable within 0-20 mA and ±10 V
- 24 Vdc powered
|
Two-input Adder
M2ADS
CE UL cUL RoHS
- Y = K1X1 + K2X2
- Specific input range within +/-300 V
- 100-240 Vac or 24 Vdc powered
- UL/cUL Class I, Div. 2 approval
|
Two-input Subtractor
M2SBS
CE UL cUL RoHS
- Y = K1X1 - K2X2
- Specific input range within +/-300 V
- 100-240 Vac or 24 Vdc powered
- UL/cUL Class I, Div. 2 approval
|
Two-input Multiplier
M2MLS
CE UL cUL RoHS
- Y = K1X1 x K2X2
- Specific input range within +/-300 V
- 100-240 Vac or 24 Vdc powered
- UL/cUL Class I, Div. 2 approval
|
Two-input Divider
M2DIS
CE UL cUL RoHS
- Y = K1X1 / K2X2
- Specific input range within +/-300 V
- 100-240 Vac or 24 Vdc powered
- UL/cUL Class I, Div. 2 approval
|
Ratio / Bias Function, Output Bias
M2REB
CE UL cUL RoHS
- Y = KX + B (positive), Y = KX + B + 100% (negative)
- Specific input range within +/-30 V; current input with a resistor.
- 100-240 Vac or 24 Vdc powered
- Easy & simple settig with the front digital meter
- UL/cUL Class I, Div. 2 approval
|
Ratio / Bias Function, Input Bias
M2RTS
CE UL cUL RoHS
- Y = K(X + B) (positive), Y = K(X + B) + 100% (negative)
- Specific input range within +/-30 V; current input with a resistor.
- 100-240 Vac or 24 Vdc powered
- Easy & simple settig with the front digital meter
- UL/cUL Class I, Div. 2 approval
|
Square Root Extractor
M2FL / M2FLS
CE UL cUL RoHS
- Specific input range within +/-300 V; current input with a resistor.
- 100-240 Vac or 24 Vdc powered
- UL/cUL Class I, Div. 2 approval
M2FL
 |
M2FLS
 |
|
High / Low Limiter
M2LMS
CE UL cUL RoHS
- Specific input range within +/-30 V; current input with a resistor.
- 100-240 Vac or 24 Vdc powered
- High & Low limits independently adjustable within -10.0 to +105%
- Easy & simple settig with the front digital meter
- UL/cUL Class I, Div. 2 approval
|
Inverted Output, Simple Loop Test Output
M2UDS2
CE RoHS
- Specific input range within +/-300 V;
current input with a resistor.
- 100-240 Vac or 24 Vdc powered
|
Inverted Output
M2UDS
CE UL cUL RoHS
- Specific input range within +/-300 V;
current input with a resistor.
- 100-240 Vac or 24 Vdc powered
- UL/cUL Class I, Div. 2 approval
|
Delay Buffer (first order lag output)
M2CDS
CE UL cUL RoHS
- Specific input range within +/-300 V;
current input with a resistor.
- 100-240 Vac or 24 Vdc powered
- Time constant adjustable within 0.5-20 sec.
- UL/cUL Class I, Div. 2 approval
|
Ramp Buffer (constant response)
M2CRS
CE UL cUL RoHS
- Specific input range within +/-300 V;
current input with a resistor.
- 100-240 Vac or 24 Vdc powered
- Rate-of-change adjustable within 0.5-40 sec.
- UL/cUL Class I, Div. 2 approval
|
Track or Hold, Simple Loop Test Output
M2AMS2
CE RoHS
- Specific input range within +/-300 V;
current input with a resistor.
- 100-240 Vac or 24 Vdc powered
- Holds the output once the command is received until reset
|
Track or Hold
M2AMS
CE UL cUL RoHS
- Specific input range within +/-300 V;
current input with a resistor.
- 100-240 Vac or 24 Vdc powered
- Holds the output once the command is received until reset
- UL/cUL Class I, Div. 2 approval
|
Peak/Valley Hold, Simple Loop Test Output
M2PHS2
CE RoHS
- Specific input range within +/-300 V;
current input with a resistor.
- 100-240 Vac or 24 Vdc powered
- Responds only to increasing/decreasing signals
|
Peak/Valley Hold
M2PHS
CE UL cUL RoHS
- Specific input range within +/-300 V;
current input with a resistor.
- 100-240 Vac or 24 Vdc powered
- Responds only to increasing/decreasing signals
- UL/cUL Class I, Div. 2 approval
|
High or Low Signal Selector, Simple Loop Test Output
M2SES2
CE RoHS
- 1-5 V, 4-20 mA, 2-10 mA, 1-5 mA, 10-50 mA input
- 100-240 Vac or 24 Vdc powered
- Selects either higher or lower of two input signals
|
High or Low Signal Selector
M2SES
CE UL cUL RoHS
- 1-5 V, 4-20 mA, 2-10 mA, 1-5 mA, 10-50 mA input
- 100-240 Vac or 24 Vdc powered
- Selects either higher or lower of two input signals
- UL/cUL Class I, Div. 2 approval
|
Analog Switching Module
M2MNV
CE RoHS
- Switches between two analog signal channels by an external contact signal
- Switches/Distributes one voltage signal to two channels
- 100-240 Vac or 24 Vdc powered
Applications: Switching 1-5V DC signal: no contact failure that happens when using mechanical contacts for this purpose; Switching low-speed pulse signals
|
Parameter Generator
M2MST
CE RoHS
- Generates a constant reference signal within the specified full-scale range
- Parameter setting is simple and easy over the entire signal range by using the front UP/DOWN switches with a help of the digital indicator.
- Specific range is ordered within 0-20 mA and ±10 V
- 100-240 Vac or 24 Vdc powered
Applications: Simple solution as a simulated signal source instead of using expensive calibrators; Used also to supply a constant reference parameter for computers and DCS
|