Isolate & Convert
 Signal Conditioners

isolate_menu
Unique I/O & Special Functions
VA   Data Sheet
VA 50 mA Output
  • Specific input within ±300 V; current input with a resistor
  • Non-isolated 10-50 mAdc output
  • 100, 110, 120, 200, 220, 240 Vac powered

Applications: Interfacing between 10-50 mA and 4-20 mA systems

SVA CE Data Sheet
SVA 200 mA Output
  • Specific input within ±300 V; current input with a resistor
  • Isolated 10-50 mA, 0-50 mA, 0-100 mA, 0-200 mA, 0-20 Vdc output
  • 100-120 V, 200-240 Vac or 110 Vdc powered

Applications: Retrofitting 10-50 mAdc control system; DC excitation for an electromagnetic coil which demands a high power; Driving actuators used in turbines, speed governors, and vari-axial fan control actuators; Valve positioners/actuators utilized in hydraulic equipment requiring 0-200 mAdc signal conversion from a standard DC signal level

99SVA   Data Sheet
99SVA 1 A Output
  • Specific input within ±300 V; current input with an internal resistor
  • Isolated 0-1 Adc output
  • 85-264 Vac powered
  • 50% zero & span adjustments
  • Low heat emission design (12W with maximum load)

Applications: Driving hydraulic machinery; Remote setting for testing equipment

SVB CE Data Sheet
99SVA 30 V Output
  • Specific input within ±300 V; current input with a resistor
  • Specific output within ±20 mA or -20 to +30 V
  • 1500 ohm load resistance at 20 mA output
  • 100-240 Vac or 24 Vdc powered
  • Fast response 25 msec. optional
  • 0-100 % output LCD display optional
TOP
CVRTD   Data Sheet
CVRTD RTD Output
  • Emulates the RTD resistance proportional to a DC signal
  • 4-20 mA or 1-5 Vdc input
  • Pt 100 equivalent resistance output
  • 100, 110, 115, 120, 200, 220, 240 Vac or 12, 24, 48 Vdc powered
  • Response time 0.5 seconds or less
  • Output drive circuit with semiconductor switches ensures long life span
  • Fixed output at power failure

Applications: Controlling an RTD input device with a DC signal

Product Features
TOP
CVR1   Data Sheet
CVR1 Potentiometer Output
  • 0-10 V, 0-1 V, 0-5 V, 1-5 Vdc input; current input with a resistor
  • 135, 1k, 100, 200, 500, 2k, 5k, 10k, 20k, 50k, 100k ohms output
  • 85-132 Vac powered
  • Permissible wattage 1W

Applications: Remote setting for inverters; Remote setting for Honeywell’s Modutrol motors; Remote setting for various instruments with potentiometer settings

Product Features
TOP
MXS   Data Sheet
MXS Self-synch Input
  • Converts position signal from a self-synchronizing motor into a DC signal proportional to the rotating shaft position
  • Input range selectable within 0-360 degrees
  • Output selectable within 0-20 mA and ±10 V
  • 85-132 V or 170-264 Vac powered
  • Linearization
  • Loop test output

Applications: Position indicator using self-synch for valves and gates; Tank gauge; Sounding level meter

Product Features
TOP
M2MNV CE Data Sheet
M2MNV Analog Switching Module
  • Switches between two analog signal channels by an external contact signal
  • Switches/Distributes one voltage signal to two channels
  • 100-240 Vac or 24 Vdc powered

Applications: Switching 1 – 5V DC signal: no contact failure that happens when using mechanical contacts for this purpose; Switching low-speed pulse signals

MNV   Data Sheet
MNV Analog Switching Module
  • Selects one signal as output from up to four analog input signals
  • Distributes a single input signal to any or all of the up to four output channels
  • ±10 Vdc input, minimum span 10mV, 50 mA max.
  • 100, 110, 115, 120, 200, 220, 240 Vac or 12, 24, 48 Vdc powered

Applications: Switching 1 – 5V DC signal without worrying about contact failures that happen when using mechanical contacts for this purpose; Switching low-speed pulse signals; Switching alternating signals

MFS2   Data Sheet
MFS2 Split-Range Transmitter
  • Generates four isolated signals which could control multiple final control elements
  • V-shape and parallel output characteristics
  • 4-20 mA input
  • 85-264 Vac or 24, 110 Vdc powered

Applications: Balancing two final control elements in opposite actions used in heating-cooling or humidifying-dehumidifying processes

Product Features
MFS   Data Sheet
MFS Split-Range Transmitter
  • Generates two signals which control two final control elements
  • V-shape and parallel output characteristics
  • 4-20 mA input
  • 12-20 mA and 4-12 mA (inverted with V-shape) outputs
  • 100, 110, 115, 120, 200, 220, 240 Vac or 24 Vdc powered

Applications: Balancing two final control elements in opposite actions used in heating-cooling or humidifying-dehumidifying processes

Product Features
TOP
M2MST CE Data Sheet
M2MST Parameter Generator
  • Generates a constant reference signal within the specified full-scale range
  • Parameter setting is simple and easy over the entire signal range by using the front UP/DOWN switches with a help of the digital indicator.
  • Specific range is ordered within 0-20 mA and ±10 V
  • 100-240 Vac or 24 Vdc powered

Applications: Simple solution as a simulated signal source instead of using expensive calibrators; Used also to supply a constant reference parameter for computers and DCS

MXMS CE Data Sheet
MXMS Programmed Ramp Generator
  • Generates various patterns of output by front UP-DOWN key programming
  • Max. 16-point-segment ramps can be generated
  • Output selectable within 0-20 mA and ±10 V.
  • 100-240 Vac, 12-24 Vdc, or 110 Vdc powered
  • Loop test output

Applications: Parameters setting for computers and DCS; Signals used in a panel, which are rarely changed.

AD3V CE Data Sheet
AD3V 16-bit Parallel Digital Output
  • BCD, binary, reflected binary, two's complement outputs selectable
  • Open collector or CMOS for output levels
  • Output can be scaled and displayed in convenient engineering unit
  • 100-240 Vac, 12-24 Vdc, or 110 Vdc powered
  • Loop test output
  • Response time adjustable within 0.15 and 60 sec.

Applications: Interface of analog signal to computers and PLC; Input to a digital panel meter

TOP
DA3 CE Data Sheet
DA3 16-bit Parallel Digital Input
  • BCD, binary, offset binary, two's complement, reflected binary inputs
  • Positive or negative logic selectable
  • Display can be scaled in convenient engineering unit
  • 100-240 Vac, 12-24 Vdc, or 110 Vdc powered

Applications: Interface of analog signal for computers and PLC

Series Guide | Isolation | Universal | DC | Temperature 4-wire Xmtr | Temperature 2-wire Xmtr |
Pulse | Strain Gauge | Potentiometer | AC | Pneumatic | Function | Power Supply | Unique & Special