Isolate & Convert
 Signal Conditioners

isolate_menu
DC mV, V, mA input Application Notes Temperature INDEX
RTD outputComparison Chart
Mini-M Series Mini-M Series
Compact Signal Conditioners
Mini-MW Series Signal Splitters
PC Programmable
More info
4-Wire, Two isolated outputs

More info
  • Wide selection of I/O ranges
  • Fill-in-the-blank programming with PC based configurator (M2X)
  • Two independent ranges can be specified with signal splitters.
  • Reference junction compensation performed on the terminals - Not inside the module
  • 2000 Vac isolation
  • Base socket included with modules

M5 / B5 Series M5 / B5 / W5 Series
Low Cost, Low Profile, Compact Modules
4-wire
More info
2-wire
More info
Two isolated outputs
More info
  • Only 41 mm (1.6 in.) deep modules can be installed anywhere, even behind a panel cover.
  • 2000 Vac isolation
TOP
M3 Series M3L / M3S / B3 Series
Thin Profile Signal Conditioners
PC Programming & "One-Step Cal" Universal I/O
About One-Step Cal More info
Super-Slim Isolator, Fixed Range & PC Programmable Type
More info
Output Loop Powered, DIP Switch Configurable
More info
  • Wide selection of I/O ranges
  • Wide supply voltage range
  • HART & PROFIBUS-PA type available (Output Loop Powered Type)

M6 Series M6 Series
Ultra-Slim Signal Conditioners
More info
  • Selectable connection method - Euro terminal, Screw terminal or Tension-Clamp.
  • Output load resistance 550 Ω (at 4-20 mAdc)
  • Low power consumption
  • Front Power LED provided
  • The Installation Base holding eight modules supported by a common power supply
  • 2000 Vac isolation
TOP
M2X Series 27 / 26 Series
Two-wire Temperature Transmitter
PC Programmable Type
More info
Fixed Range Type
More info
  • HART programmable type available
  • Suitable for DIN B type head
  • Intrinsically safe
  • Optional LED indicator mountable on top of the transmitter

B6 Series B6U / B6U-B
Two-wire Universal Temperature Transmitters
More info
  • Plug-in two-line LCD display
  • HART programmable
  • Intrinsically safe and explosion-proof
TOP

M2XU CE / UL / cUL Data Sheet
PC Programmable, Plug-in Socket Mounted
  • DC mV, V & mA, T/C, RTD and Pot input.
  • Output selectable within 0-20 mA and ±10 V.
  • 100-240 Vac or 24 Vdc powered
  • 100-point linearization
  • UL/cUL Class I, Div. 2 approval
back
M2XUM CE Data Sheet
PC Programmable Universal Input with Modbus RTU
  • DC mV, V & mA, T/C, RTD and Pot input.
  • Output selectable within 0-20 mA and ±10 V.
  • RS-485/Modbus RTU, 38.4 kbps
  • 100-240 Vac or 24 Vdc powered.
  • 100-point linearization
Application Note
back
M2XT2 CE / UL / cUL Data Sheet
PC Programmable T/C Input
  • K, E, J, T, B, R, S, C, N, U, L, PL-II selectable
  • Output selectable within 0-20 mA and ±10 V.
  • 100-240 Vac or 24 Vdc powered
  • UL/cUL Class I, Div. 2 approval
back
M2XR2 CE / UL / cUL Data Sheet
PC Programmable RTD Input
  • Pt100, Pt1000, Pt50, Ni100, Ni508.4, Cu10 selectable.
  • Output selectable within 0-20 mA and ±10 V.
  • 100-240 Vac or 24 Vdc powered
  • UL/cUL Class I, Div. 2 approval
back
W2XR   Data Sheet
PC Programmable RTD Input Signal Splitter
  • Pt100, Pt1000, Pt50, Cu10 selectable.
  • Output selectable within 0-20 mA and ±10 V.
  • 100-240 Vac or 24 Vdc powered
back
M2TS CE / UL / cUL Data Sheet
Fixed Range T/C Input
  • Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable.
  • 100-240 Vac or 24 Vdc powered
  • Fast response 25 msec. optional
  • UL/cUL Class I, Div. 2 approval
back
W2TS CE / UL / cUL Data Sheet
Fixed Range T/C Input Signal Splitter
  • Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable.
  • Independent current/voltage output ranges can be specified.
  • 100-240 Vac or 24 Vdc powered
  • Fast response 25 msec. optional
  • UL/cUL Class I, Div. 2 approval
back
M2RS CE / UL / cUL Data Sheet
Fixed Range RTD Input
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable.
  • 100-240 Vac or 24 Vdc powered
  • Fast response 25 msec. optional
  • UL/cUL Class I, Div. 2 approval
back
W2RS CE / UL / cUL Data Sheet
Fixed Range RTD Input Signal Splitter
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable.
  • Independent current/voltage output ranges can be specified.
  • 100-240 Vac or 24 Vdc powered
  • Fast response 25 msec. optional
  • UL/cUL Class I, Div. 2 approval
back
M5TS CE Data Sheet
Fixed Range T/C Input, Low Cost
  • Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable.
  • 100-240 Vac or 24 Vdc powered (CE for 24 Vdc type)
  • Fast response 25 msec. optional
back
M5RS CE Data Sheet
Fixed Range RTD Input, Low Cost
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable.
  • 100-240 Vac or 24 Vdc powered (CE for 24 Vdc type)
  • Fast response 25 msec. optional
back
W5TS CE Data Sheet
Fixed Range T/C Input Signal Splitter, Low Cost
  • Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable.
  • Independent output ranges selectable
  • CE marking for 24 Vdc powered
  • Fast response 25 msec. optional
back
W5RS CE Data Sheet
Fixed Range RTD Input Signal Splitter, Low Cost
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable.
  • Independent output ranges selectable
  • CE marking for 24 Vdc powered
  • Fast response 25 msec. optional
back
M3LU CE / UL / cUL Data Sheet
PC Programming & "One-Step Cal" Universal I/O
  • DC mV, V & mA, T/C, RTD, Pot and resistance input
  • Output selectable within 0-20 mA and ±10 V
  • 100-240 Vac or 24 Vdc powered (UL/cUL for 24 Vdc type)
  • DIP switch or PC configuration
  • 128-point linearization (DC input) using the PC Configurator (1000 points for T/C, 500 points for RTD)
back
M3LT CE / UL / cUL Data Sheet
PC & "One-Step Cal" Programmable T/C Input
  • K, E, J, T, B, R, S, C, N, U, L, PL-II selectable
  • Output selectable within 0-20 mA and ±10 V
  • 10-32 Vdc powered
  • DIP switch or PC configuration
  • 300-point linearization using the PC Configurator
back
M3LR CE / UL / cUL Data Sheet
PC & "One-Step Cal" Programmable RTD Input
  • Pt100-1000, Pt50, Ni100, 120, 508.4, Ni-Fe 604, Cu10 selectable
  • Output selectable within 0-20 mA and ±10 V
  • 10-32 Vdc powered
  • DIP switch or PC configuration
  • 300-point linearization using the PC Configurator
back
M3SXT CE Data Sheet
PC Programmable T/C Input, Super-Slim Type
  • K, E, J, T, B, R, S, N selectable
  • Output selectable within 0-20 mA and ±10 V.
  • 100-240 Vac / 24 Vdc universal power input
back
M3SXR CE Data Sheet
PC Programmable RTD Input, Super-Slim Type
  • Pt100, Pt1000, Pt50, Cu10 selectable.
  • Output selectable within 0-20 mA and ±10 V.
  • 100-240 Vac / 24 Vdc universal power input
back
M3SRS CE Data Sheet
Fixed Range RTD Input, Super-Slim Type
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable.
  • 100-240 Vac / 24 Vdc universal power input
  • Fast response 25 msec. optional
back
M6SXT (Tension-Clamp Type) CE Data Sheet
M6NXT (Screw Terminal Type) CE Data Sheet
M6DXT (Euro Terminal Type) CE Data Sheet
PC Programmable T/C Input, Ultra-Slim Type
  • K, E, J, T, B, R, S, N selectable
  • Output selectable within 0-20 mA and ±10 V.
  • 24 Vdc powered
back
M6SXR (Tension-Clamp Type) CE Data Sheet
M6NXR (Screw Terminal Type) CE Data Sheet
M6DXR (Euro Terminal Type) CE Data Sheet
PC Programmable RTD Input, Ultra-Slim Type
  • Pt100, Pt1000, Pt50, Cu10 selectable.
  • Output selectable within 0-20 mA and ±10 V.
  • 24 Vdc powered
back
27HU CE / ATEX / FM / SIL2 Data Sheet
Universal Temperature Input, HART Programmable, I/S
  • DC mV, V & mA, T/C, RTD and resistance input.
  • 8-35 Vdc powered (max. 28 V approved)
  • ATEX Zone 0 approval
  • FM Class I, Div. 1 & Zone 0 approval
back
27HU-B CE / ATEX / FM / SIL2 Data Sheet
Universal Temperature Input, HART Programmable, Explosion-proof
  • DC mV, V & mA, T/C, RTD and resistance input.
  • 8-35 Vdc powered (max. 32 V approved)
  • NEMA 4X, IP65 enclosure
  • LED indicator optional
  • ATEX Zone 0 approval
  • FM Class I, II, III, Div. 1 approval
back
27U CE / ATEX / SIL2 Data Sheet
Output Loop Powered, PC Programmable Universal Temperature Input
  • DC mV, V & mA, T/C, RTD and resistance input.
  • 9-35 Vdc powered
  • ATEX Zone 0 approval
back
27TS CE / ATEX / SIL2 Data Sheet
Output Loop Powered, PC Programmable T/C Input
  • K, E, J, T, B, R, S, C, D, N, U, L selectable
  • 9-35 Vdc powered
  • ATEX Zone 0 approval
back
27RS CE / ATEX / SIL2 Data Sheet
Output Loop Powered, PC Programmable RTD Input, Isolated
  • Pt100, Pt1000, Pt500 selectable.
  • Function monitor LED optional
  • 9-35 Vdc powered
  • ATEX Zone 0 approval
back
27R CE / ATEX / SIL2 Data Sheet
Output Loop Powered, PC Programmable RTD Input
  • Pt100, Pt1000, Pt500 selectable. Non-isolated.
  • Function monitor LED optional
  • 9-35 Vdc powered
  • ATEX Zone 0 approval
back
B6U CE / ATEX / FM Data Sheet
Universal Temperature Input, HART Programmable, I/S
  • DC mV, V & mA, T/C, RTD, Pot and resistance input.
  • 12-42 Vdc powered (max. 28 V approved)
  • ATEX Zone 0 approval
  • FM Class I, Div. 1 & 2 approval
back
B6U-B CE / ATEX / FM Data Sheet
Universal Temperature Input, HART Programmable, Explosion-proof
  • DC mV, V & mA, T/C, RTD, Pot and resistance input.
  • 12-42 Vdc powered (max. 28 V approved)
  • NEMA 4X, IP65 enclosure
  • ATEX Zone 0 approval
  • FM Class I, II, III, Div. 1 & Class I, II, Div. 2 approval
back
26TS1 CE Data Sheet
Output Loop Powered, Fixed Range T/C Input
  • Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable.
  • 12-32 Vdc powered
  • Fast response 25 msec. optional
back
26RS CE Data Sheet
Output Loop Powered, Fixed Range RTD Input, Isolated
  • Specify Pt100, Pt50, Ni 508.4 and temp. range.
  • 12-32 Vdc powered
  • Fast response 25 msec. optional
back
26R1 CE Data Sheet
Output Loop Powered, Fixed Range RTD Input
  • Pt100 input. Select temp. range. Non-isolated.
  • 8.5-32 Vdc powered
  • Economical model
back
26REX CE / ATEX Data Sheet
Output Loop Powered, Fixed Range RTD Input, Intrinsically Safe
  • Pt100 input. Select temp. range. Non-isolated.
  • 12-30 Vdc powered.
  • ATEX Zone 0 approval
back
B3HU CE / ATEX / FM Data Sheet
Universal Temperature Input, HART Programmable
  • mV, V, T/C, RTD, resistance and potentiometer input
  • 12-42 Vdc powered (max. 28 V approved)
  • ATEX Zone 0 approval
back
B3PU CE Data Sheet
Universal Temperature Input, PROFIBUS-PA
  • mV, V, T/C, RTD, resistance and potentiometer input
  • 9-30 Vdc powered
back
B3FT CE / UL / cUL Data Sheet
Output Loop Powered, DIP Switch Configurable T/C Input
  • K, J, T or E, R, N selectable
  • 12-45 Vdc powered
back
B3FR CE / UL / cUL Data Sheet
Output Loop Powered, DIP Switch Configurable RTD Input
  • Pt100, Ni120, Cu10 selectable
  • 12-45 Vdc powered
back
B5TS CE Data Sheet
Output Loop Powered, Fixed Range T/C Input, Low Cost
  • Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable.
  • 12-28 Vdc powered
  • Fast response 25 msec. optional
back
B5RS CE Data Sheet
Output Loop Powered, Fixed Range RTD Input, Low Cost
  • Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable.
  • 12-28 Vdc powered
  • Fast response 25 msec. optional
back
Application Notes Temperature INDEX
RTD outputComparison Chart
TOP
Unique & Special
DC | Temperature | Pulse| Strain Gauge| Potentiometer | AC | Pneumatic| Function|Power Supply
Copyright (C)2003-2006 M-System Co., Ltd. All rights reserved.
Power Supply Function Pneumatic AC Potentiometer Strain Gauge Pulse Temperature DC Unique & Special